WHAT'S IN THE BOX
1x WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)
NOTES FROM MT EXPERT
Fully Shrouded Terminals
OVERVIEW
WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)
Suitable for use when total RCD protection is required to supplement the system earthing and where local 30mA RCDs are used to give additional protection. Contact position indication on the dolly handle. Time delay will discriminate with the 30mA RCD.
DIN Rail Mounted Fitting
Type S Curve
Fully Shrouded Terminals
2-Module Size
Test Button
Brand
Wylex
CSU Device
RCDs
Curve Type
Type S
Earth Leakage Sensitivity (IDn)
100 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Lifeline
Model No
SFWRMT100/2
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
Time Delay RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
100 A
Rated Operational Voltage (Ue)
230 V
Suitable Cable Size
50 mm²
WHAT'S IN THE BOX
1x WYLEX 80A 30MA DP TYPE A RCD (384HV)
NOTES FROM MT EXPERT
DIN Rail Mounted Fitting
OVERVIEW
WYLEX 80A 30MA DP TYPE A RCD (384HV)
18th Edition Amendment 2. Double pole DC sensitive RCD. Features test button. Multi-wired connectable conductor cross-section: 35mm².
DIN Rail Mounted Fitting
Type A Curve
Brand
Wylex
Breaking Capacity (Inc)
0 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model No
SFWRDS80/2
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
80 A
Rated Operational Voltage (Ue)
230 V
Suitable Cable Size
50 mm²
WHAT'S IN THE BOX
1x WYLEX 63A 30MA DP TYPE A RCD (528VF)
NOTES FROM MT EXPERT
Plug-In Fitting
OVERVIEW
WYLEX 63A 30MA DP TYPE A RCD (528VF)
18th Edition Amendment 2. Type A plug-in RCD. Fully shrouded terminals with contact position indication on dolly handle.
Plug-In Fitting
Type A Curve
Brand
Wylex
Breaking Capacity (Inc)
0 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
Plug-In
Manufacturer Guarantee
1 Year Guarantee
Model No
GB6:SFWRDS63/2
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
63 A
Rated Operational Voltage (Ue)
230 V
Suitable Cable Size
50 mm²
WHAT'S IN THE BOX
1x WYLEX 100A 30MA DP TYPE A RCD (424HV)
NOTES FROM MT EXPERT
DIN Rail Mounted Fitting
OVERVIEW
WYLEX 100A 30MA DP TYPE A RCD (424HV)
18th Edition Amendment 2. Double pole DC sensitive RCD. Two-module size with test button. Multi-wired connectable conductor cross-section: 35mm².
DIN Rail Mounted Fitting
Type A Curve
Brand
Wylex
Breaking Capacity (Inc)
4 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model No
SFWRDS100/2
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
100 A
Rated Operational Voltage (Ue)
230 V
Suitable Cable Size
50 mm²
WHAT'S IN THE BOX
1x SCHNEIDER ELECTRIC EASY9 63A 30MA DP TYPE AC RCD (6280P)
NOTES FROM MT EXPERT
Type AC Curve
OVERVIEW
SCHNEIDER ELECTRIC EASY9 63A 30MA DP TYPE AC RCD (6280P)
Protects several circuits when fitted upstream of a group of circuit breakers. Tripping in case of leakage current only.
DIN Rail Mounted Fitting
Type AC Curve
Positive Contact Indication
Brand
Schneider Electric
Breaking Capacity (Inc)
3 kA
CSU Device
RCDs
Curve Type
Type AC
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Easy9
Model No
EZ9R33263
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
63 A
Rated Operational Voltage (Ue)
230 V
Suitable Cable Size
35 mm²
WHAT'S IN THE BOX
1x CONTACTUM DEFENDER 63A 30MA DP TYPE A RCD (363HA)
NOTES FROM MT EXPERT
Tested to 10,000 volts and guaranteed to 1,000 volts. Tested against cold to -40°
OVERVIEW
CONTACTUM DEFENDER 63A 30MA DP TYPE A RCD (363HA)
18th Edition Amendment 2. Suitable for use in Defender consumer units. DIN rail mounted. Designed to function where up to 6mA of DC leakage current may also be present.
DIN Rail Mounted Fitting
Type A Curve
Brand
Contactum
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Defender
Model No
CPR63A
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
63 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
up to 25 mm²
WHAT'S IN THE BOX
1x CONTACTUM DEFENDER 100A 30MA DP TYPE A RCD (767HA)
NOTES FROM MT EXPERT
DIN Rail Mounted Fitting
OVERVIEW
CONTACTUM DEFENDER 100A 30MA DP TYPE A RCD (767HA)
18th Edition Amendment 2. Suitable for use in Defender consumer units. DIN rail mounted. Designed to function where up to 6mA of DC leakage current may also be present.
DIN Rail Mounted Fitting
Type A Curve
Brand
Contactum
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Defender
Model No
CPR100A
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
100 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
up to 25 mm²
WHAT'S IN THE BOX
1x BRITISH GENERAL FORTRESS 80A 30MA DP TYPE A RCD (835HV)BRITISH GENERAL FORTRESS 80A 30MA DP TYPE A RCD (835HV)
NOTES FROM MT EXPERT
Tested to 10,000 volts and guaranteed to 1,000 volts. Tested against cold to -40°
OVERVIEW
MILWAUKEE 4932464565 VDE LONG 45 DEGREE ROUND NOSE PLIERS 205MM
18th Edition Amendment 2. For use on equipment incorporating electronic components. Can detect and respond as per AC Type, plus equipment with pulsating DC components.
DIN Rail Mounted Fitting
Type A Curve
Positive Status Indication Contact
Retrofittable
Easy Installation
Brand
British General
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Fortress
Model No
CUR8030A-01
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
80 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
Max 25 mm²
WHAT'S IN THE BOX
1x BRITISH GENERAL FORTRESS 80A 100MA DP TYPE AC RCD
NOTES FROM MT EXPERT
Have Good Quality
OVERVIEW
BRITISH GENERAL FORTRESS 80A 100MA DP TYPE AC RCD
Type AC. Double pole RCD.
FEATURE
DIN Rail Mounted Fitting
Type AC Curve
Positive Contact Status Indicator
Lockable Dolly Switch
Large Terminal Capacity
1P + N
WHAT'S IN THE BOX
1x BRITISH GENERAL FORTRESS 63A 30MA DP TYPE A RCD (189HV)
NOTES FROM MT EXPERT
Positive Status Indication Contact
OVERVIEW
BRITISH GENERAL FORTRESS 63A 30MA DP TYPE A RCD (189HV)
18th Edition Amendment 2. For use on equipment incorporating electronic components. Can detect and respond as per AC Type, plus equipment with pulsating DC components.
DIN Rail Mounted Fitting
Type A Curve
Positive Status Indication Contact
Retrofittable
Easy Installation
Brand
British General
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Fortress
Model No
CUR6330A-01
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
63 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
Max 25 mm²
WHAT'S IN THE BOX
1x BRITISH GENERAL FORTRESS 40A 30MA DP TYPE A RCD (294HV)
NOTES FROM MT EXPERT
Positive Status Indication Contact
OVERVIEW
BRITISH GENERAL FORTRESS 40A 30MA DP TYPE A RCD (294HV)
18th Edition Amendment 2. For use on equipment incorporating electronic components. Can detect and respond as per AC Type, plus equipment with pulsating DC components.
DIN Rail Mounted Fitting
Type A Curve
Positive Status Indication Contact
Retrofittable
Easy Installation
Brand
British General
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Fortress
Model No
CUR4030A-01
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
40 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
Max 25 mm²
WHAT'S IN THE BOX
1x BRITISH GENERAL FORTRESS 100A 30MA DP TYPE A RCD (101HV)
NOTES FROM MT EXPERT
Positive Status Indication Contact
OVERVIEW
BRITISH GENERAL FORTRESS 100A 30MA DP TYPE A RCD (101HV)
18th Edition Amendment 2. For use on equipment incorporating electronic components. Can detect and respond as per AC Type, plus equipment with pulsating DC components.
DIN Rail Mounted Fitting
Type A Curve
Positive Status Indication Contact
Retrofittable
Easy Installation
Brand
British General
Breaking Capacity (Inc)
6 kA
CSU Device
RCDs
Curve Type
Type A
Earth Leakage Sensitivity (IDn)
30 mA
Incomer Fitting Type
DIN Rail Mounted
Manufacturer Guarantee
1 Year Guarantee
Model Name
Fortress
Model No
CUR10030A-01
No. of Phases
Single-Phase
Number of Poles
Double Pole
Pack Size
1
Pieces in Pack/Case
1
Product Type
RCD
Rated Impulse Withstand Voltage (Uimp)
4 kV
Rated Operational Current (In)
100 A
Rated Operational Voltage (Ue)
230 V AC
Suitable Cable Size
Max 25 mm²